STATIC FREQUENCY CONVERTERS 400Hz 5 ÷ 45kVA FC400
Static frequency converters, ELIT FC series, are outcome of a long experience both in UPS and in frequency converters field.
To complete our apparatus series for airfield applications, constant current regulators for lighting system and 28.5vdc feeder
for the engine starter are available.
All of our equipments distinguish themselves by the employment of advanced technological components, excellent reliability and easy maintenance.
The simplicity of working is the main feature of all of our products.
PRINCIPLES OF WORKING
The benefit of a 400Hz electric system resides in lowered dimensions and weight respect an analogous system to 50Hz or 60Hz.
|
Benefits, these ones, very important on board of an aircraft where the space is always narrowed and it is a must minimize the weights and maximize the performances.
The FC400 static frequency converter allows to feed the aircraft on runway transforming the 50/60Hz mains voltage into a sinusoidal, stabilized and galvanic insulated 400Hz voltage.
The employ of the converter allows the electric system test, keeping OFF the aircraft's engines.
A diode rectifier transforms the AC voltage into a continuous stabilized DC link voltage, to power the IGBT inverter that transforms the continuous voltage into a 400Hz alternating sinusoidal stabilized voltage with a PWM modulation. The output inverter voltage feeds a transformer which on its output have the filter capacitors.
The output voltage is sinusoidal with a distortion of 3%. The output has an electronic stabilization both in voltage and in frequency.
FEATURES
. High efficiency >93%;
. Filtered, stabilized and regulated sine wave supply;
. 400Hz ± 0.01% frequency accuracy;
. Input power factor >0,95;
. Wide input voltage window and input frequency window;
. Superior overload capability;
. Insulation transformer;
. LCD display;
. Emergency Power Off.
OPTIONS
. Drop line compensation;
. Local aircraft interlock circuit with bypass;
. Remote control terminal board;
. No Break Power Transfer;
. Neutral conductor rupture supervision;
. Battery version (UPS);
. Protection degree IP 54;
. Horizontal or mobile version;
. Additional 28Vdc module output;
. RS232, USB, RS485 & SNMP interfaces.
|
|
|
CONTROL PANEL
The control panel is divided in three parts:
- LCD display (PMD);
- LED indicators
- Keyboard.
LCD display
LCD backlit. Display is subdivided into four menus which are accessible by pressing the relevant function keys:
- Voltage phase voltage, active Energy, linked voltage, reactive voltage phase voltage min. value and max value, harmonic distortion phase voltage;
- Current phase current, active energy, phase current demand, reactive energy, phase current max demand, neutral current, harmonic distortion phase current;
- Power Active, reactive, apparent power, phase active power, reactive energy, phase reactive power, phase apparent power, active, reactive apparent power demand and max demand;
- Power factor;
- Frequency ;
- Working hours and minutes;
- Positive and negative active Energy;
- Positive and negative reactive Energy.
LED signaling
- Mains;
- frequency converter running;
- frequency converter alarm.
Keyboard
Possibility to select the desired menu, to load a customized display page and modify the programmable parameters.
INTERFACES
The apparatus are provided with a dry contact to remote the following signaling:
- frequency converter alarm;
- frequency converter running;
- ON/OFF remote control.
Optional modules:
- RS485 communication;
- RS232 communication;
- Profibus communication;
- Lonworks communication;
- Pulse output;
- Analog output;
- Alarms;
- Neutral current.
|
MONITORING CONTROL SYSTEM (as option)
ELITAVIO manages communication from and to remote devices, distributed in two ways:
. Physical connections;
. Wireless connections.
These two kinds of connections can be combined at any way, to use in the better way the available
infrastructures for the application (telephone cable, ADSL/HDSL connections, optic fiber cable, GSM/GPRS modem, UMTS modem, HSPDA modem).
The System can use two dedicated lines by cable, optic fiber or it can use a point of access through LAN network
or internet in remote plant allowing the management with automatic calling or through request of the control device.
The Workstation logs on Central System through LAN or Internet network allowing the complete compatibility of the System.
ELITAVIO has a Client platform, designed for mobile phones, with Java ELITMobile platform. It allows to access directly with
the phone to all data of the Server and to perform all maintenance actions in remote.
The Central System controls every access with login procedure, classifying them in different levels according the
operative level that you desire to give at each user.
CUSTOM VERSION
We realize custom apparatus according to customer's technical data employing the
standard series sets and therefore with experimented feature:
Fixed or variable input Voltage;
Fixed or variable output voltage;
Outdoor protection degree;
Extended temperature range -40°C to +50°C;
UPS version;
Parallel version;
Parallel cabinet with system switches;
Voltage fine regulation (potentiometer);
Frequency fine regulation (potentiometer);
Distribution cabinet;
Drop line compensator cabinet;
Mobile Version;
Under Bridge version;
Output 28Vdc voltage.
|
|
|
Model |
FC400
5 |
FC400
7.5 |
FC400
10 |
FC400
15 |
FC400
20 |
FC400
25 |
FC400
30 |
FC400
45 |
Rated power kVA/kW |
5/4 |
7.5/6 |
10/8 |
15/12 |
20/16 |
25/20 |
30/24 |
45/36 |
|
|
|
|
|
|
|
|
|
INPUT |
|
Nominal voltage |
400V 3F
(208, 480 and 575V as option) |
Voltage tolerance |
±15% |
Power factor |
>0.95 at nominal load |
Nominal frequency |
50Hz , 60Hz ±5% |
Current distortion |
<30% (<10% as option) |
Inrush current |
Absent |
|
|
|
|
|
|
|
|
|
OUTPUT |
|
Voltage |
400Vca,
200V 3F+N
(115, 480 and 575V as option) |
Frequency
|
400Hz ± 0.01% |
Power factor |
0.7 lagging to 0.95 leading |
Waveform |
Sinusoidal |
Total harmonic distortion |
<3% with linear load |
Static stability |
±1% |
Dynamic stability |
±8% |
Recovery time |
2
msec. |
Overload |
125% for 10 minutes, 150% for 1 minute |
Voltage symmetry |
±1% with balanced load, ±2% with 30% unbalanced load |
Crest factor |
1.414 ±3% |
|
|
|
|
|
|
|
|
|
MISCELLANEOUS |
|
Dimensions WxDxH |
600x800x1200mm |
Weight kgs |
5kVA 100kg |
7.5kVA 110kg |
10kVA 120kg |
15kVA 180kg |
20kVA 250kg |
25kVA 270kg |
30kVA 300kg |
45kVA 450kg |
Overall efficiency |
>93% |
Noise level |
<65dBA |
Operating temperature |
-25°C ÷ +50°C |
Relative humidity |
0 from 95% without condensing |
Altitude |
1000m without derating |
Protection degree |
IP20 (IP31, IP41 and IP54 on request) |
Cooling |
Forced air |
|
|
|
|
|
|
|
|
|
STANDARDS |
|
Performance |
ISO 6858, MIL-STD-704, EN 2282 |
EMC
|
EN 61000-6-4, EN62040-2, EN 61000-6-2, EN 61000-4-3/4/5 |
Safety |
EN 62040-1-1, EN 61558-2-6 |
|
|
|
|
|
|
|
|
|
USER INTERFACE |
|
Input |
Circuit breaker |
Output
|
Switch (contactor on request) |
Selector |
ON/OFF |
Output meter
|
Voltage, current, frequency
(minimum and max voltage, current demand, max current demand, average current, current harmonic distortion,
three phase power, phase power, power factor, run hour, active and reactive energy)
|
Signaling |
Mains, converter running, converter alarm
(output converter connected on request)
|
Potentiometers |
Voltage fine regulation and frequency fine regulation on request |
Remote control |
ON/OFF converter |
|
|
|
|
|
|
|
|
|
AVAILABLE OPTIONS |
Additional output module 400Hz
Additional output module 28Vdc till 800 A
No Break Power Transfer (NBPT)
Generative loads
Remote Control Terminal Board
Mobile or bridge mounted configuration
Extended temperature range -40°C to 50°C
UPS version with battery
Parallel kit version
Local aircraft interlock circuit
Local and remote drop line compensation
Neutral conductor rupture supervision
|
|
ELIT Srl reserves his right to do modifications to his
products without notice |
download the pdf |
 |
ask for a quotation |
 |
|
|