STATIC FREQUENCY CONVERTERS 400 Hz

Static frequency converters 120  ÷ 315kVA FC400

STATIC FREQUENCY CONVERTERS
400Hz 120 ÷ 315kVA FC400


Static frequency converters, ELIT FC series, are outcome of a long experience both in UPS and in frequency converters field. To complete our apparatus series for airfield applications, constant current regulators for lighting system and 28.5vdc feeder for the engine starter are available. All of our equipments distinguish themselves by the employment of advanced technological components, excellent reliability and easy maintenance. The simplicity of working is the main feature of all of our products.

PRINCIPLES OF WORKING

The benefit of a 400Hz electric system resides in lowered dimensions and weight respect an analogous system to 50Hz or 60Hz.

Benefits, these ones, very important on board of an aircraft where the space is always narrowed and it is a must minimize the weights and maximize the performances. The FC400 static frequency converter allows to feed the aircraft on runway transforming the 50/60Hz mains voltage into a sinusoidal, stabilized and galvanic insulated 400Hz voltage. The employ of the converter allows the electric system test, keeping OFF the aircraft's engines. A diode rectifier transforms the AC voltage into a continuous stabilized DC link voltage, to power the IGBT inverter that transforms the continuous voltage into a 400Hz alternating sinusoidal stabilized voltage with a PWM modulation. The output inverter voltage feeds a transformer which on its output have the filter capacitors. The output voltage is sinusoidal with a distortion of 3%. The output has an electronic stabilization both in voltage and in frequency.

FEATURES


. High efficiency >93%;
. Filtered, stabilized and regulated sine wave supply;
. 400Hz ± 0.01% frequency accuracy;
. Input power factor >0,95;
. Wide input voltage window and input frequency window;
. Superior overload capability;
. Insulation transformer;
. LCD display;
. Emergency Power Off.

OPTIONS


. Drop line compensation;
. Local aircraft interlock circuit with bypass;
. Remote control terminal board;
. No Break Power Transfer;
. Neutral conductor rupture supervision;
. Battery version (UPS);
. Protection degree IP 54;
. Horizontal or mobile version;
. Additional 28Vdc module output;
. RS232, USB, RS485 & SNMP interfaces.


CONTROL PANEL

The control panel is divided in three parts:
- LCD display (PMD);
- LED indicators
- Keyboard.

display

LCD display
LCD backlit. Display is subdivided into four menus which are accessible by pressing the relevant function keys:
- Voltage phase voltage, active Energy, linked voltage, reactive voltage phase voltage min. value and max value, harmonic distortion phase voltage;
- Current phase current, active energy, phase current demand, reactive energy, phase current max demand, neutral current, harmonic distortion phase current;
- Power Active, reactive, apparent power, phase active power, reactive energy, phase reactive power, phase apparent power, active, reactive apparent power demand and max demand;
- Power factor;
- Frequency ;
- Working hours and minutes;
- Positive and negative active Energy;
- Positive and negative reactive Energy.

LED signaling
- Mains;
- frequency converter running;
- frequency converter alarm.

Keyboard
Possibility to select the desired menu, to load a customized display page and modify the programmable parameters.

INTERFACES

The apparatus are provided with a dry contact to remote the following signaling:
- frequency converter alarm;
- frequency converter running;
- ON/OFF remote control.

Optional modules:
- RS485 communication;
- RS232 communication;
- Profibus communication;
- Lonworks communication;
- Pulse output;
- Analog output;
- Alarms;
- Neutral current.

MONITORING CONTROL SYSTEM (as option)

ELITAVIO manages communication from and to remote devices, distributed in two ways:

. Physical connections;
. . Wireless connections.

These two kinds of connections can be combined at any way, to use in the better way the available infrastructures for the application (telephone cable, ADSL/HDSL connections, optic fiber cable, GSM/GPRS modem, UMTS modem, HSPDA modem).
The System can use two dedicated lines by cable, optic fiber or it can use a point of access through LAN network or internet in remote plant allowing the management with automatic calling or through request of the control device.
The Workstation logs on Central System through LAN or Internet network allowing the complete compatibility of the System.
ELITAVIO has a Client platform, designed for mobile phones, with Java ELITMobile platform. It allows to access directly with the phone to all data of the Server and to perform all maintenance actions in remote.
The Central System controls every access with login procedure, classifying them in different levels according the operative level that you desire to give at each user.

CUSTOM VERSION

We realize custom apparatus according to customer's technical data employing the standard series sets and therefore with experimented feature:

Fixed or variable input Voltage;
Fixed or variable output voltage;
Outdoor protection degree;
Extended temperature range -40°C to +50°C;
UPS version;
Parallel version;
Parallel cabinet with system switches;
Voltage fine regulation (potentiometer);
Frequency fine regulation (potentiometer);
Distribution cabinet;
Drop line compensator cabinet;
Mobile Version;
Under Bridge version;
Output 28Vdc voltage.


Model FC400 120 FC400
150
FC400
180
FC400
200
FC400
220
FC400
270
FC400
315
Rated power kVA/kW 120/96 150/120 180/144 200/160 220/176 270/216 315/252
               
INPUT  
Nominal voltage 400V 3F
(208, 480 and 575V as option)
Voltage tolerance ±15%
Power factor >0.95 at nominal load
Nominal frequency 50Hz , 60Hz ±5%
Current distortion <30% (<10% as option)
Inrush current Absent
               
OUTPUT  
Voltage 400Vca, 200V 3F+N
(115, 480 and 575V as option)
Frequency 400Hz ± 0.01%
Power factor 0.7 lagging to 0.95 leading
Waveform Sinusoidal
Total harmonic distortion <3% with linear load
Static stability ±1%
Dynamic stability ±8%
Recovery time 2 msec.
Overload 125% for 10 minutes, 150% for 1 minute
Voltage symmetry ±1% with balanced load, ±2% with 30% unbalanced load
Crest factor 1.414 ±3%
               
MISCELLANEOUS  
Dimensions WxDxH 120kVA 150kVA 180kVA 200kVA 220kVA 270kVA 315kVA
1200x600x1800mm 1500x950x1850mm
Weight kgs 900kg 950kg 1300kg 1500kg 1800kg 2170kg 2250kg
Overall efficiency >93%
Noise level 68dBA 70dBA
Operating temperature -25°C ÷ +50°C
Relative humidity 0 from 95% without condensing
Altitude 1000m without derating
Protection degree IP20
(IP31, IP41 and IP54 on request)
Cooling Forced air
               
STANDARDS  
Performance ISO 6858, MIL-STD-704, EN 2282
EMC EN 61000-6-4, EN62040-2, EN 61000-6-2, EN 61000-4-3/4/5
Safety EN 62040-1-1, EN 61558-2-6
               
USER INTERFACE  
Input Circuit breaker
Output Switch
(contactor on request)
Selector ON/OFF
Output meter Voltage, current, frequency
(minimum and max voltage, current demand, max current demand, average current, current harmonic distortion, three phase power, phase power, power factor, run hour, active and reactive energy)
Signaling Mains, converter running, converter alarm
(output converter connected on request)
Potentiometers Voltage fine regulation and frequency fine regulation on request
Remote control ON/OFF converter
               
AVAILABLE OPTIONS Additional output module 400Hz
Additional output module 28Vdc till 800 A
No Break Power Transfer (NBPT)
Generative loads
Remote Control Terminal Board
Mobile or bridge mounted configuration
Extended temperature range -40°C to 50°C
UPS version with battery
Parallel kit version
Local aircraft interlock circuit
Local and remote drop line compensation
Neutral conductor rupture supervision

ELIT Srl reserves his right to do modifications to his products without notice


scarica il pdf pdf ask for a quotation preventivo