MULTIVOLTAGE STATIC FEEDER FOR RAILWAY CARRIAGE TESTING DATA SHEET

1. Features
The purpose of the apparatus is to provide, from the mains voltage 400V, the four voltages emploied on the european carriage: 3000Vdc, 1500Vdc, 1500Vac and 1000Vac 16,6Hz. These voltages are stabilized and manually settable.
2. Technical data
• Input voltage: 400V 3F
• Input voltage range: ± 15%
• Input frequency: ± 5%
• Rated powe: 100kW
   
• OUTPUT VOLTAGE 1: 3000V corrente continua
• Range settable: 1620Vcc ÷ 4255Vcc
• Static stability ± 1,5%
• Dynamic stability (with load variation ± 60%): ± 8%
• Ripple (RMS): 4%
• Overload for 10 minutes: 125%
• Short circuit current: 150%
   
• OUTPUT VOLTAGE 2: 1500V corrente continua
• Range settable: 810Vcc ÷ 2155Vcc
• Static stability: ± 1,5%
• Dynamic stability (with load variation ± 60%): ± 8%
• Ripple (RMS): 4%
• Overload for 10 minutes: 125%
• Short circuit current: 150%
   
• OUTPUT VOLTAGE 3: 1500V monofase
• Range settable: 1140V ÷ 1760V
• Nominal frequency: 50Hz ± 0,5Hz
• Waveform: sinusoidale
• THD: 5%
• Static stability: ± 1,5%
• Dynamic stability (with load variation ± 60%): ± 8%
• Overload for 10 minutes: 125%
• Short circuit current: 150%
   
• OUTPUT VOLTAGE 4: 1000V monofase
• Range settable: 600V ÷ 1100V
• Nominal frequency: 16,6Hz ± 0,5Hz
• Waveform: sinusoidale
• THD: 5%
• Stabilità statica: ± 1,5%
• Dynamic stability (with load variation ± 60%): ± 8%
• Overload for 10 minutes: 125%
• Short circuit current: 150%
 
3. Miscellaneous
• Range working temperature: -5°C ÷ +45°C
• Max temperature daily average: 35°C
• Altitude without downgrading: 1000m
• Relative humidity at 45°C (without condensing): 90%
• Dimensions: 2000x950x1850mm
• Weight: 1500kg
• Losses: 10kW
 
4. 4. Meters
• DC voltmeter
• DC amperometer
• AC voltmeter (50Hz, 16,6Hz)
• AC amperometer (50Hz, 16,6Hz)
• Frequency meter
 
5. Signalling
• Working converter
• Fault converter
• Overtemperature
• 3000Vdc switch on
• 1500Vdc switch on
• 1500Vac 50Hz switch on
• 1000Vac 16,6Hz switch on
 
6. Telealarms (on request)
• Working converter
• Fault converter
• Overtemperature
• 3000Vdc switch on
• 1500Vdc switch on
• 1500Vac 50Hz switch on
• 1000Vac 16,6Hz switch on
 
7. Local controls
• Key selector 3000Vdc selection
• Key selector 1500Vdc selection
• Key selector 1500Vac 50Hz selection
• Key selector 1000Vac 16,6Hz selection
• Calibration 3000Vdc
• Calibration 1500Vdc
• Calibration 1500Vac 50Hz
• Calibration 1000Vac 16,6Hz
 
8. Switches
• Input automatic breaker with locked key.
• Output switch at two positions: output connected to converter/ output connected to the ground. Double locked keys with keys switched and locked for on position.


ELIT Srl reserves his right to do modifications to his products without notice