MULTIVOLTAGE STATIC FEEDER FOR RAILWAY CARRIAGE TESTING DATA SHEET

1. Features
The purpose of the apparatus is to provide, from the mains voltage 400V, the four voltages emploied on the european carriage: 3000Vdc, 1500Vdc, 1500Vac and 1000Vac 16,6Hz. These voltages are stabilized and manually settable.
2. Technical data
Input voltage: 400V 3F
Input voltage range: ± 15%
Input frequency: ± 5%
Rated powe: 100kW
   
OUTPUT VOLTAGE 1: 3000V corrente continua
Range settable: 1620Vcc ÷ 4255Vcc
Static stability ± 1,5%
Dynamic stability (with load variation ± 60%): ± 8%
Ripple (RMS): 4%
Overload for 10 minutes: 125%
Short circuit current: 150%
   
OUTPUT VOLTAGE 2: 1500V corrente continua
Range settable: 810Vcc ÷ 2155Vcc
Static stability: ± 1,5%
Dynamic stability (with load variation ± 60%): ± 8%
Ripple (RMS): 4%
Overload for 10 minutes: 125%
Short circuit current: 150%
   
OUTPUT VOLTAGE 3: 1500V monofase
Range settable: 1140V ÷ 1760V
Nominal frequency: 50Hz ± 0,5Hz
Waveform: sinusoidale
THD: 5%
Static stability: ± 1,5%
Dynamic stability (with load variation ± 60%): ± 8%
Overload for 10 minutes: 125%
Short circuit current: 150%
   
OUTPUT VOLTAGE 4: 1000V monofase
Range settable: 600V ÷ 1100V
Nominal frequency: 16,6Hz ± 0,5Hz
Waveform: sinusoidale
THD: 5%
Stabilità statica: ± 1,5%
Dynamic stability (with load variation ± 60%): ± 8%
Overload for 10 minutes: 125%
Short circuit current: 150%
 
3. Miscellaneous
Range working temperature: -5°C ÷ +45°C
Max temperature daily average: 35°C
Altitude without downgrading: 1000m
Relative humidity at 45°C (without condensing): 90%
Dimensions: 2000x950x1850mm
Weight: 1500kg
Losses: 10kW
 
4. 4. Meters
DC voltmeter
DC amperometer
AC voltmeter (50Hz, 16,6Hz)
AC amperometer (50Hz, 16,6Hz)
Frequency meter
 
5. Signalling
Working converter
Fault converter
Overtemperature
3000Vdc switch on
1500Vdc switch on
1500Vac 50Hz switch on
1000Vac 16,6Hz switch on
 
6. Telealarms (on request)
Working converter
Fault converter
Overtemperature
3000Vdc switch on
1500Vdc switch on
1500Vac 50Hz switch on
1000Vac 16,6Hz switch on
 
7. Local controls
Key selector 3000Vdc selection
Key selector 1500Vdc selection
Key selector 1500Vac 50Hz selection
Key selector 1000Vac 16,6Hz selection
Calibration 3000Vdc
Calibration 1500Vdc
Calibration 1500Vac 50Hz
Calibration 1000Vac 16,6Hz
 
8. Switches
Input automatic breaker with locked key.
Output switch at two positions: output connected to converter/ output connected to the ground. Double locked keys with keys switched and locked for on position.


ELIT Srl reserves his right to do modifications to his products without notice