MULTIVOLTAGE STATIC FEEDER FOR RAILWAY CARRIAGE TESTING
DATA SHEET |

|
1.
Features
The purpose of the apparatus is to provide, from the mains voltage 400V,
the four voltages emploied on the european carriage: 3000Vdc, 1500Vdc, 1500Vac and 1000Vac 16,6Hz.
These voltages are stabilized and manually settable. |
|
2. Technical data
|
•
Input voltage: |
400V 3F |
•
Input voltage range: |
± 15% |
•
Input frequency: |
± 5% |
•
Rated powe: |
100kW |
|
|
•
OUTPUT VOLTAGE 1: |
3000V corrente continua |
•
Range settable: |
1620Vcc ÷ 4255Vcc |
•
Static stability |
± 1,5% |
•
Dynamic stability (with load variation ± 60%): |
± 8% |
•
Ripple (RMS): |
4% |
•
Overload for 10 minutes: |
125% |
•
Short circuit current: |
150% |
|
|
•
OUTPUT VOLTAGE 2: |
1500V corrente continua |
•
Range settable: |
810Vcc ÷ 2155Vcc |
•
Static stability: |
± 1,5% |
•
Dynamic stability (with load variation ± 60%): |
± 8% |
•
Ripple (RMS): |
4% |
•
Overload for 10 minutes: |
125% |
•
Short circuit current: |
150% |
|
|
•
OUTPUT VOLTAGE 3: |
1500V monofase |
•
Range settable: |
1140V ÷ 1760V |
•
Nominal frequency: |
50Hz ± 0,5Hz |
•
Waveform: |
sinusoidale |
•
THD: |
5% |
•
Static stability: |
± 1,5% |
•
Dynamic stability (with load variation ± 60%): |
± 8% |
•
Overload for 10 minutes: |
125% |
•
Short circuit current: |
150% |
|
|
•
OUTPUT VOLTAGE 4: |
1000V monofase |
•
Range settable: |
600V ÷ 1100V |
•
Nominal frequency: |
16,6Hz ± 0,5Hz |
•
Waveform: |
sinusoidale |
•
THD: |
5% |
•
Stabilità statica: |
± 1,5% |
•
Dynamic stability (with load variation ± 60%): |
± 8% |
•
Overload for 10 minutes: |
125% |
•
Short circuit current: |
150% |
|
|
|
3. Miscellaneous
|
•
Range working temperature: |
-5°C ÷ +45°C |
•
Max temperature daily average: |
35°C |
•
Altitude without downgrading: |
1000m |
•
Relative humidity at 45°C (without condensing): |
90% |
•
Dimensions: |
2000x950x1850mm |
•
Weight: |
1500kg |
•
Losses: |
10kW |
|
|
4. 4. Meters
|
•
DC voltmeter |
•
DC amperometer |
•
AC voltmeter (50Hz, 16,6Hz) |
•
AC amperometer (50Hz, 16,6Hz) |
•
Frequency meter |
|
|
5. Signalling
|
•
Working converter |
•
Fault converter |
•
Overtemperature |
•
3000Vdc switch on |
•
1500Vdc switch on |
•
1500Vac 50Hz switch on |
•
1000Vac 16,6Hz switch on |
|
|
6. Telealarms (on request)
|
•
Working converter |
•
Fault converter |
•
Overtemperature |
•
3000Vdc switch on |
•
1500Vdc switch on |
•
1500Vac 50Hz switch on |
•
1000Vac 16,6Hz switch on |
|
|
7. Local controls
|
•
Key selector 3000Vdc selection |
•
Key selector 1500Vdc selection |
•
Key selector 1500Vac 50Hz selection |
•
Key selector 1000Vac 16,6Hz selection |
•
Calibration 3000Vdc |
•
Calibration 1500Vdc |
•
Calibration 1500Vac 50Hz |
•
Calibration 1000Vac 16,6Hz |
|
|
8. Switches
|
•
Input automatic breaker with locked key. |
•
Output switch at two positions: output connected to
converter/ output connected to the ground.
Double locked keys with keys switched and locked for on position. |
|
ELIT Srl reserves his right to do modifications to his products
without notice |
download pdf |
 |
ask for a
quotation |
 |
|